Luminar 5030 “Le Vigneron” analyser
08/16/2016
AOTF Luminar 3076 SeedMeister NIR analyzer
AOTF Luminar 3076 SeedMeister NIR Analyzer
08/16/2016

Luminar 3030 Free Space Analyzer

Description

The Luminar 3030 Free Space analyzer is a rugged AOTF-NIR spectrometer that can be inserted directly into the production line. As such, the Luminar 3030 eliminates the need for fiber optic lines.

Ideal for inline, real-time analysis, monitoring and control. The Luminar 3030 analyzer can identify the organic chemical composition, actives, starch and moisture content in a variety of products, including solids, pellets, powder and suspensions.

Ideal for spray dryer analysis of moisture compositions and particle size. For instance caffeine in decaffeinated coffee, or fat, protein, and lactose in milk powder.

Key Features

  • Insensitive to vibrations and ambient light
  • Fast scanning speed – 16,000 wavelengths per second
  • No moving parts
  • Non-invasive, non-contact measurements
  • Superior Signal-to-Noise Ratio throughout the entire spectral range 

Applications

  • Pharmaceutical: 100% inspection of solids, pastes, creams and powders
  • Food and Dairy: In-line food analysis for fat, protein, moisture
  • Drying Process: Direct placement on spray or fluid bed dryers
  • Polymer: In-site measurement of pellets, films and coatings
  • Textile: Cotton/polyester
  • Pulp and Paper: In-line thickness and coating analysis 

Luminar 3030 Free Space AOTF-NIR Process Analyzer
Spectral Range Options 600-1100 nm, 850-1700 nm, 900-1800 nm, 1100-2300 nm
Measurement Modes Diffuse Reflection
(Transmission with an attachment)
Spectral Resolution 5-10 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Repeatability ± 0.01 nm
Wavelength Increment 1-10 nm (software selectable)
Ambient Light Rejection >106
Vibration Immunity Blenders, Dryers
Agriculture field operations
Linearity 0.1%
Signal Digitization 16-bit A/D (1 part in 65,536)
Sampling Speed 16,000 wavelength/sec
Sampling Area 26 x 16 mm (Model 700),
9 x 5 mm (Model 701),
5 x 3 mm (Model 705)
Sampling Angle 25°
Diagnostics 10 Built-in monitoring sensors
Power Requirements 12VDC, (24VDC special order), 90Watts,
110VAC 60Hz,
220VAC 50Hz
Process Control Up to 16 A/D, 16 D/A Channels and 16 I/O Channels accessed via MACRO
language, D/A outputs can be supplied as isolated 4-20 mA current loop
outputs - Modbus capability (optional) (RS 422/485)
Software Package Windows-based analytical software for data acquisition
Attachments 700-23 For conversion to lab diffuse reflectance

700-25 For conversion to lab transmission measurement

700-26 Air-Flow Curtain

705-20 For transmission measurement

Download Brochure